Find suitable products for satellite and telecommunications:

Discover our full range of products:

Environmental and reliability test procedures

Through standardized and normed test procedures, we ensure that our products always work reliably and precisely, even under the most difficult conditions.

Test ProcedureDIN EN/ICEMIL STDTest Method
Vibration (10…55 Hz, 0.75 mm peak, 55…2000 Hz: 10g peak)68-2-6, Test Fc202204
Bumping (4000 shocks per axis, 40g, 6 ms, 3 axis both directions)68-2-29, Test Eb202213
Mechanical Shock68-2-27, Test Ea202213
Rapid Change of Temperature (30 min each, -40/+85°C, 10 cycles, transfer less than 1 min)68-2-14, Test Na202107
Damp Heat, Cyclic (55°C, 90% r.H. and 25°C, 95% r.H.)68-2-30, Test Db202106
Low Temperature Storage/ Cold Test (-55°C, 2 hours)68-2-1, Test Aa202107
High Tempertaure Storage/ Dry Heat (-105°C, 16 hours)68-2-2, Test Ba202108
Damp heat, Steady State (+40°C, 93% r.H., 56 days)68-2-3, Test Ca202103
Electrostatic Discharge Sensitivity, Human Body Model8833015
Soldering Heat Resistance (through-hole products)68-2-20, Test Tb202210
Soldering Heat Resistance (SMD products)IPC/JEDEC J-STD020, Method 5.6
High Temperature Aging (1000h at +85°C)679-1, 4.7.1
High quality standardKVG is certified according to the EN 9100 quality management system and the ISO 14001 environmental management system. Our high quality standards make us a reliable partner for many customers worldwide who demand HiRel products.